Green, Robert N., Donaldson, Oliver W., Dafydd, Meilyr, Evans, Samuel Lewin ![]() |
Abstract
Purpose To assess the effect of the insertion angle and the angle of applied load on the pullout strength of screw-in suture anchors. Methods Screw-in metallic suture anchors were inserted into a 10–lb/cu ft synthetic cancellous bone block at 30°, 45°, 60°, and 90° to the surface. The suture pull angle was then varied in 30° increments between 0° and 180°. Five constructs were tested to failure (anchor pullout) for each combination of angles using a Zwick tensile testing machine (Zwick Roell, Ulm, Germany). Results There were a total of 25 combinations. The greatest pullout strength was seen with a suture anchor inserted at 90° to the bone block with a pull angle of 90° to the bone (mean, 306 N; standard deviation [SD], 9 N). The weakest pullout strength was seen with a suture anchor inserted at 30° with the angle of pull at 120° (i.e., opposite to the direction of insertion of the anchor) (mean, 97 N; SD, 11 N). A simulated deadman's angle of 45° with an angle of pull of 150° produced a pullout strength of 127 N (SD, 4 N). The pullout strengths for each insertion angle were greatest when the angle of pull was similar to the angle of insertion (P < .0001, repeated-measures analysis of variance). Conclusions The angle of applied load to a suture anchor and the insertion angle significantly influence the biomechanical pullout strength of screw-in suture anchors. The insertion angle of the suture anchor should replicate the angle of applied load to ensure the optimum pullout strength.
Item Type: | Article |
---|---|
Date Type: | Publication |
Status: | Published |
Schools: | Engineering |
Subjects: | T Technology > TJ Mechanical engineering and machinery |
Publisher: | Elsevier |
ISSN: | 0749-8063 |
Last Modified: | 28 Oct 2022 08:59 |
URI: | https://orca.cardiff.ac.uk/id/eprint/72906 |
Citation Data
Cited 28 times in Scopus. View in Scopus. Powered By Scopus® Data
Actions (repository staff only)
![]() |
Edit Item |