Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Computing the orientational-average of diffusion-weighted MRI signals: a comparison of different techniques

Afzali, Maryam, Knutsson, Hans, Ozarslan, Evren and Jones, Derek K ORCID: https://orcid.org/0000-0003-4409-8049 2021. Computing the orientational-average of diffusion-weighted MRI signals: a comparison of different techniques. Scientific Reports 11 , 14345. 10.1038/s41598-021-93558-1

[thumbnail of s41598-021-93558-1.pdf] PDF - Published Version
Available under License Creative Commons Attribution.

Download (2MB)

Abstract

Numerous applications in diffusion MRI involve computing the orientationally-averaged diffusion-weighted signal. Most approaches implicitly assume, for a given b-value, that the gradient sampling vectors are uniformly distributed on a sphere (or ‘shell’), computing the orientationally-averaged signal through simple arithmetic averaging. One challenge with this approach is that not all acquisition schemes have gradient sampling vectors distributed over perfect spheres. To ameliorate this challenge, alternative averaging methods include: weighted signal averaging; spherical harmonic representation of the signal in each shell; and using Mean Apparent Propagator MRI (MAP-MRI) to derive a three-dimensional signal representation and estimate its ‘isotropic part’. Here, these different methods are simulated and compared under different signal-to-noise (SNR) realizations. With sufficiently dense sampling points (61 orientations per shell), and isotropically-distributed sampling vectors, all averaging methods give comparable results, (MAP-MRI-based estimates give slightly higher accuracy, albeit with slightly elevated bias as b-value increases). As the SNR and number of data points per shell are reduced, MAP-MRI-based approaches give significantly higher accuracy compared with the other methods. We also apply these approaches to in vivo data where the results are broadly consistent with our simulations. A statistical analysis of the simulated data shows that the orientationally-averaged signals at each b-value are largely Gaussian distributed.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Psychology
Cardiff University Brain Research Imaging Centre (CUBRIC)
Publisher: Nature Research
ISSN: 2045-2322
Funders: Wellcome Trust
Date of First Compliant Deposit: 29 June 2021
Date of Acceptance: 28 June 2021
Last Modified: 06 May 2023 17:19
URI: https://orca.cardiff.ac.uk/id/eprint/142210

Citation Data

Cited 4 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics