Transparency of the bovine corneal stroma at physiological hydration and its dependence on concentration of the ambient anion

Kostyuk, O., Nalovina, O., Mubard, T. M., Regini, Justyn Wiktor ORCID: https://orcid.org/0000-0001-6149-5893, Meek, Keith Michael Andrew ORCID: https://orcid.org/0000-0002-9948-7538, Quantock, Andrew James ORCID: https://orcid.org/0000-0002-2484-3120, Elliott, Gerald and Hodson, Stuart Arthur 2002. Transparency of the bovine corneal stroma at physiological hydration and its dependence on concentration of the ambient anion. The Journal of Physiology 543 (2) , pp. 633-642. 10.1113/jphysiol.2002.021527

Full text not available from this repository.

Abstract

De-epithelialised and de-endothelialised bovine corneal stromas with a hydration of 3.2 equilibrated at 154 mM NaCl and buffered at pH 7.4 had their optical density (400–750 nm) measured. Stromas equilibrated against 10, 20, 30, 50 or 100 mM NaCl made isotonic to 154 mM NaCl by supplementing with sorbitol were progressively more transparent as NaCl increased. Hypertonic equilibration against 300, 600 or 1000 mM NaCl resulted in a progressive loss of transparency compared with 154 mM NaCl. Light scattering as a function of wavelength fitted a l_3 function well for 10, 30, 50, 100 and 154 mM NaCl preparations between 450 and 650 nm, but not at higher wavelengths. However, hypertonic 300, 600 and 1000 mM NaCl preparations showed a l_2 dependence in the 450–750 nm range. Experiments with 154 mM NaCl and either 0 or 300 mM sorbitol suggested that the changes in light scattering in hypertonic preparations are unlikely to be caused by osmotic alterations to the stromal keratocytes. Psychophysical studies of the optical transmission function of preparations indicated that corneal stromas dialysed against 154 mMNaCl had usable optical properties, but preparations dialysed against 10 mMNaCl were effectively unable to transmit an image. The results are related to the known increase of fixed negative charge in the corneal matrix when chloride ions are adsorbed onto the matrix. It is suggested that the ordering force between corneal collagen fibrils, generated in part by anion binding, may be crucial to the physiological functioning of the visual system.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Optometry and Vision Sciences
Biosciences
Subjects: R Medicine > RE Ophthalmology
Publisher: The Physiological Society
ISSN: 0022-3751
Last Modified: 20 Oct 2022 09:53
URI: https://orca.cardiff.ac.uk/id/eprint/33438

Citation Data

Cited 41 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item