Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

A pitfall in the reconstruction of fibre ODFs using spherical deconvolution of diffusion MRI data

Parker, Greg, Marshall, Andrew David ORCID: https://orcid.org/0000-0003-2789-1395, Rosin, Paul L. ORCID: https://orcid.org/0000-0002-4965-3884, Drage, Nicholas, Richmond, Stephen ORCID: https://orcid.org/0000-0001-5449-5318 and Jones, Derek K. ORCID: https://orcid.org/0000-0003-4409-8049 2013. A pitfall in the reconstruction of fibre ODFs using spherical deconvolution of diffusion MRI data. NeuroImage 65 , pp. 433-448. 10.1016/j.neuroimage.2012.10.022

Full text not available from this repository.

Abstract

Diffusion weighted (DW) MRI facilitates non-invasive quantification of tissue microstructure and, in combination with appropriate signal processing, three-dimensional estimates of fibrous orientation. In recent years, attention has shifted from the diffusion tensor model, which assumes a unimodal Gaussian diffusion displacement profile to recover fibre orientation (with various well-documented limitations), towards more complex high angular resolution diffusion imaging (HARDI) analysis techniques. Spherical deconvolution (SD) approaches assume that the fibre orientation density function (fODF) within a voxel can be obtained by deconvolving a ‘common’ single fibre response function from the observed set of DW signals. In practice, this common response function is not known a priori and thus an estimated fibre response must be used. Here the establishment of this single-fibre response function is referred to as ‘calibration’. This work examines the vulnerability of two different SD approaches to inappropriate response function calibration: (1) constrained spherical harmonic deconvolution (CSHD)—a technique that exploits spherical harmonic basis sets and (2) damped Richardson–Lucy (dRL) deconvolution—a technique based on the standard Richardson–Lucy deconvolution. Through simulations, the impact of a discrepancy between the calibrated diffusion profiles and the observed (‘Target’) DW-signals in both single and crossing-fibre configurations was investigated. The results show that CSHD produces spurious fODF peaks (consistent with well known ringing artefacts) as the discrepancy between calibration and target response increases, while dRL demonstrates a lower over-all sensitivity to miscalibration (with a calibration response function for a highly anisotropic fibre being optimal). However, dRL demonstrates a reduced ability to resolve low anisotropy crossing-fibres compared to CSHD. It is concluded that the range and spatial-distribution of expected single-fibre anisotropies within an image must be carefully considered to ensure selection of the appropriate algorithm, parameters and calibration. Failure to choose the calibration response function carefully may severely impact the quality of any resultant tractography.

Item Type: Article
Status: Published
Schools: Computer Science & Informatics
Cardiff University Brain Research Imaging Centre (CUBRIC)
Dentistry
Psychology
Subjects: Q Science > QA Mathematics > QA75 Electronic computers. Computer science
R Medicine > RC Internal medicine > RC0321 Neuroscience. Biological psychiatry. Neuropsychiatry
T Technology > TA Engineering (General). Civil engineering (General)
Uncontrolled Keywords: Spherical harmonic deconvolution; Richardson–Lucy; MRI; Calibration; Tractography; Diffusion tensor imaging
Publisher: Elsevier
ISSN: 1053-8119
Last Modified: 10 Nov 2023 12:47
URI: https://orca.cardiff.ac.uk/id/eprint/48588

Citation Data

Cited 87 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item